-layout: page
-permalink: /external/lab-equipment/cold-traps
-shortcut: lab:cold-traps
-redirect_from:
-  - /cards/lab-equipment:maintenance_of_cold_traps
-  - /external/cards/lab-equipment:maintenance_of_cold_traps
-  - /lab/maintenance_of_cold_traps
-  - /external/external/lab-equipment/maintenance_of_cold_traps/
-  - /cards/lab:maintenance_of_cold_traps
-  - /external/cards/lab:maintenance_of_cold_traps
-  - /external/lab-equipment/maintenance_of_cold_traps/
-  - /cards/lab-equipment:cold-traps
-  - /external/cards/lab-equipment:cold-traps
-  - /lab/cold-traps
-  - /external/external/lab-equipment/cold-traps/
-  - /cards/lab:cold-traps
-  - /external/cards/lab:cold-traps
----
-
-# Cold traps: maintenance
-
-## Labconco Centrivap concentrator and cold trap
-
-The procedure describes the steps for routine maintenance of the Labconco Centrivap concentrators and cold traps.
-This maintenance is important to preserve the integrity of the glass bottles inside the cold trap.  
-
-**The Instrument care officer** is responsible for cleaning the condenser once a year, changing the acid filter when necessary and filling the cold trap maintenance record sheet.  
-
-**The Users** are responsible for the routine maintenance of the instrument and filling the “cold trap maintenance record sheet”.  
-
-## Description  
-
-To ensure proper functioning of the centrivap concentrators and associated cold trap, a routine maintenance is necessary:  
-
-<div align=center>
-
-**_Personal Protective Equipment_**:  
-Lab coat  
-Nitrile gloves
-
-</div>
-
-1.	This routine maintenance is performed by the users of the instrument.  
-2.	If a glass bottle is used inside the cold trap, add 99% ethanol to the stainless steel trap until the glass bottle is at least two-thirds immersed.  
-3.	At the end of each week, the cold trap should be switched off and the condensed solvent in the glass bottle should be discarded in the corresponding waste container.  
-4.	If there is any ice in the stainless steel trap (outside the glass bottle), let it melt, drain the ethanol and replace it with fresh ethanol.
-To drain, use the faucet on the left side of the cold trap.  
-
-<div align="center">
-<img src="img/cold-trap_img_1.png" height="250">
-</div>  
-
-5.	Fill the “cold trap maintenance record sheet “ (Appendix 01)  
-6.	Restart the cold trap at the beginning of the following week
-
-**Once a year, the refrigeration system condenser of the Cold trap should be cleaned.**  
-
-<div align=center>
-
-**_Personal Protective Equipment_**:  
-Lab coat  
-Nitrile gloves  
-Safety goggles  
-
-</div> 
-
-1.	This step is performed by a maintenance officer  
-2.	Switch off the instrument  
-3.	Use a vacuum cleaner with brush attachment  
-4.	Clean the condenser (on the left side of the cold trap) to ensure proper airflow for peak performance
-
-<div align="center">
-<img src="img/cold-trap_img_2.png" height="250">
-</div>  
-
-5.	Fill the “cold trap maintenance record sheet “ (Appendix 01)
-When necessary, the acid cartridge (LIMS ID: 10608) should be exchanged  
-
-* When the cartridge looks wet (see arrow on the following picture), it should be exchanged for a new one.  
-
-<div align="center">
-<img src="img/cold-trap_img_3.png" height="250">
-</div>  
-
-* This is done by a maintenance officer  
-* Switch off the instrument  
-* Unscrew the black cap out of the transparent container  
-* Remove the cartridge and replace it with the new one  
-* Close back the container  
-* Place the old cartridge in the chemical hood for evaporation in a retention container  
-* 24 hours later, trash it in a blue bin UN3291  